Magnetic Solid Phase Extraction Based O.n Ferroferric Oxide/Nitrogen-Doped Graphene F or Determination Of Six Kinds Of Carbonyl Compounds In Water Samples
文献类型: 外文期刊
作者: Cao, XJ; Zhou, T; Xu, JH; Chai, YF; Ye, XM
作者机构:
关键词: Nitrogen-doped graphene; Magnetic solid-phase extraction; High resolution mass spectrometry; Carbonyl compounds
期刊名称: CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
ISSN: 0253-3820
年卷期: 2019 年 47 卷 3 期
页码:
收录情况: JCR(2021版) ; EI(2021版) ; 北大核心(2020版) ; CSCD(2020-2021年度) ; 科技核心(2020版)
摘要: In combination with 2, 4-dinitrophenylhydrazine ( DNPH ) pre-column derivatization, an ultrasound-assisted magnetic solid phase extraction method with Fe3O4 -grafted nitrogen-doped graphene (Fe3O4/N-G) nanomaterials as magnetic adsorbent was developed for the determination of acetone , acrolein , butenal, n-butanal, cyclohexanone and hexanal in environmental water samples by ultra performance liquid chromatography-high resolution mass spectrometry ( UPLC-HRMS) . The derivation conditions were optimized by single-factor experiments as follows ; the pH of water sample was adjusted to 3. 0 , and derivatization was performed for 40 min at 40 degrees C with 500 times of DNPH. As a result, the conversion ratios of 6 carbonyl compounds were in the range of 52. 1% -86. 6% . Several significant factors that affected the magnetic solidphase extraction efficiency including the amount of magnetic nanoparticles , salt concentration and kinds of desorption solvent were also optimized using a response surface methodology. The optimal conditions were as follows ; 4. 7 mg of Fe3O4/N-G was dispersed into 100 mL of water with ultrasonic extraction for 10 s. Then the adsorbents were separated by a magnet and eluted with 2 mL of acetonitrile. Finally , the eluent was dried under a mild stream of nitrogen gas and reconstituted with acetonitrile and water ( 1 : 1 , V/V) for the subsequent UPLC-HRMS analysis. It was obvious that the excessive DNPH could be almost eliminated by the MPSE process. Under the optimal conditions , a good linearity was obtained in the concentration range of 2-100 ng/L, with correlation coefficients ranged from 0. 9980 to 0. 9995. The limits of detection ( LOQs, S/N= 3) and the limits of quantification ( LOQs, S/N = 10) ranged from 0. 05 to 0. 20 ng/L and 0. 20 to 0.96 ng/L, respectively. The average recoveries at three spiked levels ranged from 74. 1% to 101. 0% with the inter- and intra-day precisions ( n=6 ) of less than 6. 3% . Moreover, the trace level of acetone , acrolein , butenal, n-butanal, and hexanal in real water samples has been successfully detected using the proposed method. Attributed to the excellent performances of Fe3O4/N-G, the proposed method was demonstrated to be simple, quick and high sensitive 14 the trace analysis of carbonyl compounds in water samples.
分类号:
- 相关文献
作者其他论文 更多>>
-
Taxonomic And Phylogenetic Characterizations Reveal Three New Species Of Mendogia (Myriangiaceae, Myriangiales)
作者:Jiang, HB; Phookamsak, R; Xu, JH; Karunarathna, SC; Mortimer, PE; Hyde, KVD
关键词:3 New Species; Bambusicolous Fungi; Dothideomycetes; Phylogeny; Taxonomy
-
Dissipation Pattern And Safety Evaluation Of Cartap And Its Metabolites During Tea Planting, Tea Manufacturing And Brewing
作者:Dai, JX; Jiang, CL; Gao, GW; Zhu, L; Chai, YF; Chen, HP; Liu, X
关键词:Tea; Cartap; Metabolites; Dissipation; Maximum Residual Levels
-
Impact Of Cropland Displacement On The Potential Crop Production In China: A Multi-Scale Analysis
作者:Yang, BH; Ke, XL; van Vliet, J; Yu, QY; Zhou, T; Verburg, PH
关键词:Land Use Change; Cropland Displacement; Potential Crop Production; Land Use Policy; Food Security
-
Determination Of Polychlorinated Biphenyls In Tea Using Gas Chromatography-Tandem Mass Spectrometry Combined With Dispersive Solid Phase Extraction
作者:Gao, GW; Chen, HP; Dai, JX; Jin, LL; Chai, YF; Zhu, L; Liu, X; Lu, CY
关键词:Tea; Polychlorinated Biphenyls; Dispersive Solid Phase Extraction; Gas Chromatography - Tandem Mass Spectrometry
-
Effects Of 1-Methylcyclopropene Combined With Modified Atmosphere On Quality Of Fig (Ficus Carica L.) During Postharvest Storage
作者:Song, CC; Li, A; Chai, YF; Li, QP; Lin, Q; Duan, YQ
关键词:
-
Fluorometric Determination Of Rnase H V.ia A Dnazyme Conjugated T o Reduced Graphene Oxide, And Its Application To Screening Forinhibitors And Activators
作者:Tong, CY; Zhou, T; Zhao, C; Yuan, LQ; Xu, Y; Liu, B; Fan, JL; Li, D; Zhu, AG
关键词:Fluorescent probe; Nanomaterial; Signal amplification; Quenching efficiency; Tumor cell lines; High sensitivity; Concentration-dependent manner; Model docking; Kinetic analysis; Hepatitis C virus
-
Simultaneous Determination Of Cartap And I.ts Metabolite In Tea U sing Hydrophilic Interaction Chromatography Tandem Mass Spectrometry And The Combination Of Dispersive Solid Phase Extraction And Solid Phase Extraction
作者:Dai, JX; Chen, HP; Gao, GW; Zhu, L; Chai, YF; Liu, X
关键词:Tea; Cartap; Nereistoxin; Hydrophilic interaction chromatography tandem mass spectrometry; Solid phase extraction