Direct Determination Of Ultratrace Arsenic In Blood Samples Using An In-Situ Dielectric Barrier Discharge Trap Coupled With Atomic Fluorescence Spectrometry
文献类型: 外文期刊
作者: Liu, MT; Mao, XF; Liu, JX; Ding, L; Na, X; Chen, GY; Qian, YZ
作者机构:
期刊名称: ATOMIC SPECTROSCOPY
ISSN: 0195-5373
年卷期: 2019 年 40 卷 3 期
页码:
收录情况: JCR(2021版)
摘要: A novel direct sampling hydride generation (HG) system was utilized and is first reported to introduce a blood sample into a in-situ dielectric barrier discharge atomic fluorescence spectrometer (DBD-AFS) for ultratrace determination of arsenic based on the gas phase enrichment (GPE) principle. The in-situ DBD unit was fitted with three concentric quartz tubes to replace the conventional atomizer in the AFS. Followed by a simple disruption for 2 minutes and centrifugation for 8 minutes of the blood sample in 3% HNO3 (v:v) extractant, the arsenic extraction and protein precipitation can be achieved up to 40 multiple dilutions. A supernatant consisting of 5% HCl (v:v) and 5 g/L KBH4 in 1.5 g/L KOH was introduced into the HG-in-situ DBD-AFS. Then, arsenic generating from the HG was trapped using 11 kV DBD at 110 mL/min air, swept for 190 seconds at 500 mL/min Ar, and released with 13 kV at 180 mL/min H-2. Under the optimal conditions, the linear regression coefficient (R-2) was 0.996 ranging from 0.05 to 300 mu g/L. The method detection limit (LOD) obtained was 7 pg arsenic, with a 3.9% precision using 11 repeated measurements for real blood samples. The spiked recoveries for the real blood samples were 96-107%. Furthermore, it was found that the arsenic concentrations measured by the proposed method were not significantly different (P > 0.05) from using microwave digestion in ECP-MS. The complete analysis, including sample pre-treatment, was performed within 15 minutes. The results show that the proposed method offers a fast and reliable analysis of ultratrace levels of arsenic in real blood samples.
分类号:
- 相关文献
作者其他论文 更多>>
-
Poly(N-Acryloyl-Glucosamine-Co-Methylenebisacrylamide)-Based Hydrophilic Magnetic Nanoparticles For The Extraction Of Aminoglycosides In Meat Samples
作者:Liu, HY; Li, N; Liu, XB; Qian, YZ; Qiu, J; Wang, XN
关键词:Hydrophilic Magnetic Nanoparticles; Hydrophilic Interaction Solid Phase Extraction; Aminoglycosides; Animal-Derived Food
-
A Comprehensive Analysis Of Metabolomics And Transcriptomics Reveals New Biomarkers And Mechanistic Insights On Dehp Exposures In Mcf-7 Cells
作者:Lu, YS; Yao, GX; Wang, XL; Liu, JX; Yu, J; Qiu, J; Li, Y; Qian, YZ; Xu, YY
关键词:Metabolomics; Transcriptomics; Mcf-7; Proliferation Effect; Dehp
-
Profiling Of Organosulfur Compounds And Amino Acids In Garlic From Different Regions Of China
作者:Liu, PX; Weng, R; Sheng, XJ; Wang, XL; Zhang, WH; Qian, YZ; Qiu, J
关键词:Allium Sativum L.; Organosulfur Compounds; Amino Acids; Uhplc-Ms/Ms; Multivariate Data Analysis
-
Benefit-Risk Assessment Of Dietary Selenium And Its Associated Metals Intake In China (2017-2019): Is Current Selenium-Rich Agro-Food Safe Enough?
作者:Zhang, LQ; Song, HX; Guo, YB; Fan, B; Huang, YT; Mao, XF; Liang, KH; Hu, ZQ; Sun, XD; Fang, Y; Mei, XH; Yin, HQ; Li, BR; Wang, YT; Liu, XJ; Lu, BY
关键词:Selenium; Metal; Safety; Population; Dietary Intake
-
Rapid Screening Analysis Of Methylmercury In Fish Samples Using Stannous Chloride Reduction And Direct Sampling Electrothermal Vaporization Atomic Absorption Spectrometry
作者:Li, SQ; Hao, CC; Xing, PZ; Xia, XL; Liu, TP; Mao, XF
关键词:
-
A-To-I Rna Editing In Bacteria Increases Pathogenicity And Tolerance To Oxidative Stress
作者:Nie, WH; Wang, S; He, R; Xu, Q; Wang, PH; Wu, Y; Tian, F; Yuan, JH; Zhu, B; Chen, GY
关键词:
-
A Novel Strategy Of Anti-Interference For Solid Dilution In Elemental Analysis Using Spontaneous Surface Dispersion Theory
作者:Wang, B; Liu, TP; Liu, JX; Mao, XF; Na, X; Chen, GY; Lv, ZH; Qian, YZ
关键词: