数字农科院2.0

On-Line Microplasma Decomposition Of Gaseous Phase Interference For Solid Sampling Mercury Analysis In Aquatic Food Samples

文献类型: 外文期刊

作者: Liu, TP; Liu, MT; Liu, JX; Mao, XF; Zhang, SS; Shao, YB; Na, X; Chen, GY; Qian, YZ

作者机构:

关键词: Dielectric Barrier Discharge Microplasma; Volatile Organic Compounds Decomposition; Solid Sampling Electrothermal Vaporization; Mercury; Aquatic Food Samples

期刊名称: ANALYTICA CHIMICA ACTA

ISSN: 0003-2670

年卷期: 2020 年 1121 卷

页码:

收录情况: JCR(2021版) ; EI(2021版)

摘要: In this work, dielectric barrier discharge (DBD) was first utilized to eliminate gaseous phase interference from complicated solid sample. So, a novel solid sampling Hg analyzer was first designed using a coaxial DBD reactor to replace catalytic pyrolysis furnace for sensitive mercury determination in aquatic food samples. The Hg analyzer mainly comprised an electrothermal vaporizer (ETV), a DBD reactor to decompose gaseous interfering substances including volatile organic compounds (VOCs), a gold-coil Hg trap to eliminate matrix interference and an atomic fluorescence spectrometer (AFS) as detector. These units were connected by a manifold integrating air and Ar/H-2 (v/v = 9 : 1), fulfilling on-line decomposition of up to 12 mg dried aquatic food powder at ambient temperature. The proposed method detection limit (LOD) was 0.5 mu g/kg and the relative standard deviations (RSDs) were within 5% for Hg standards as well as within 10% for real samples, indicating adequate analytical sensitivity and precision. In addition, the on-line DBD reactor consumes only 40 W, which is obviously lower than that (>300 W) of the commercial Hg analyzers; including the sample pre-treatment, the overall analysis could be completed within 5 min. This method is easier, greener and safer for Hg analysis in real samples obviating chemical reagents. The new DBD apparatus can facilitate the miniaturization and portability with low power consumption and instrumental size revealing its promising potential in direct Hg analysis instrumentation development. (C) 2020 Elsevier B.V. All rights reserved.

分类号:

  • 相关文献

[1]Dulplex Analysis Of Mercury And S.ilver Ions Using A L abel-Free Fluorescent Aptasensor. Zhang, J, Huang, YF, Yan, J, Zhu, C, Zhang, CH, Chen, AL. 2018

[2]Development Of Semi. Quantitative Solid S.ampling Mercury Analyzer For C osmetics. Wang, B, Liu, JX, Zhang, XH, Mao, XF, Ding, L, Na, X. 2018

[3]Simultaneous Determination Of Heavy Metals By An Electrochemical Method Based On A Nanocomposite Consisting Of Fluorinated Graphene And Gold Nanocage. Tan, Z, Wu, WQ, Feng, CQ, Wu, HM, Zhang, ZW. 2020

[4]Lactobacillus Brevis 23017 Relieves Mercury T.oxicity In The Colon B y Modulation Of Oxidative Stress And Inflammation Through The Interplay Of Mapk And Nf-Kappa B Signaling Cascades. Jiang, XP, Gu, SS, Liu, D, Zhao, LL, Xia, S, He, XM, Chen, HY, Ge, JW. 2018

[5]Soil aggregate–associated mercury (Hg) and organic carbon distribution and microbial community characteristics under typical farmland–use types. Penggang Pei,Tao Sun,Yingming Xu,Yuebing Sun. 2021

作者其他论文 更多>>